Doncaster Single-core Voltage-drop Lookup

Calculate voltage drop using an exact public Doncaster table for named 90°C single-core copper cables. No cable selection or compliance claim.

How to use the Doncaster Single-core Voltage-drop Lookup

  1. Confirm the exact Doncaster cable and fixed published scope match the proposed run.
  2. Choose the published circuit arrangement, installation column group and conductor size.
  3. Enter design current, one-way route length and nominal voltage.
  4. Enter the voltage-drop limit allocated by the competent electrical designer and review the arithmetic comparison.

Why use this tool

  • Uses exact public manufacturer values for Doncaster 6491B and 6181XY single-core copper cable.
  • Uses the published three-phase value directly, without interpolation or a derived phase multiplier.
  • Separates transparent voltage-drop arithmetic from cable selection and compliance decisions.

This is a deliberately narrow manufacturer-table lookup, not a generic BS 7671 cable calculator. It covers Doncaster 6491B and 6181XY 90°C thermosetting, unarmoured single-core copper cable in the listed arrangements and 1–16mm² rows. The user supplies the design limit; the tool does not pick one, recommend a larger cable or decide compliance. A competent electrical designer must still verify current-carrying capacity, conductor temperature, protective devices, correction factors, fault protection and withstand, CPC, earth-fault loop impedance, disconnection time, harmonics, special locations and the current manufacturer and BS 7671 requirements before installation or energisation.

Part of Builder Tools Calculators — construction tools for UK tradespeople.